Project Description.

  • Special plant complete with :
  1. evacuator for recovery/elimination of processing waste;
  2. 2 filtration steps, 300 µm→ 50 µm;
  3. high flow rate relaunch of FLR with medium pressure;
  4. FLR thermal control unit.

Performance and key data

  • Chip type: Alloy steel
  • Chip morphology: short, long and stacked
  • Throughput of transportable swarf Ṁ= 500 kg/h
  • Type of cooling lubricant  
    6-10% oil emulsion
  • Total volumetric capacity
    V= 11,000 litres
  • Machine Tool Crankcase Washing 
    = 300 µmG.F.= 300 Lt/1' H= 8 bar Q
  • External Refrigeration = 300 µmG.F.
    = 700 Lt/1' H= 3,5 bar Q
  • Internal Refrigeration = 50 µmG.F.
    = 200-400 Lt/1' H= 20 bar Q
  • T. Constant coolant fluid at 30°C

Component description

  • NI75/650 Hinged Belt Conveyor 
  • Rotofilter UnitRTF500/800-LF 2 
    Q= 800 Lt/1' G.F.= 300 µm
  • Prefiltered Coolant Tank HD146 No. 1
    Hydrocyclone Filter = 50 µmG.F.= 600 Lt/1' Q
  • High Pressure Tank Sentinel G.F.= 60 µmMPI850Cartridge Filter TYPE
  • Clean coolant tank 
  • Thermal control unit operated with thermostatic valve and internal clean tank exchanger 
  • Cooling fluid from external cooler

Documentation and manuals

Technical Documentation and Manual in Italian and/or translations.

Request information